Spoke-type load cell ST-114
Product features:
The ST-114 square-base rim-type force measuring sensor has a low height, good rigidity, high accuracy, and strong resistance to eccentric loading.
Capacity:
2kN(200kg)、5kN(500kg)、10kN(1t)、20kN(2t)、50 kN(5t)、70 kN(7t)、100 kN(10t)、120 kN(12t)、150 kN(15t)、200 kN(20t) 、250 kN(25t)、300 kN(30t)
|
No. |
Technical Parameters |
|
|
1 |
Rated load |
2kN-300kN |
|
2 |
Total accuracy |
0.05/0.1%F.S |
|
3 |
Sensitivity |
1.5-2.0mV/V |
|
4 |
Nonlinearity |
≦0.05/0.1%F.S |
|
5 |
Repeatability |
≦0.05%F.S |
|
6 |
Hysteresis |
≦0.05/0.1%F.S |
|
7 |
Input impedance |
380Ω or 760Ω |
|
8 |
Output impedance |
350Ω or 700Ω |
|
9 |
Insulation resistance |
≥2000MΩ |
|
10 |
Temperature effect on zero |
<0.05%F.S/10℃ |
|
11 |
Temperature effect on output |
<0.05%F.S/10℃ |
|
12 |
Working temperature |
-30~70℃ |
|
13 |
Safety overload |
120%F.S |
|
14 |
Recommend excitation |
10V(DC/AC) |
|
15 |
Wiring Method |
Red... E+ (positive power supply) Black... E- (negative power supply) Green... S+ (positive signal) White... S- (negative signal) |