S-type beam load cell ST-208
Product Feature:
The ST-208 square S-type tension/compression sensor can withstand both tension and compression forces. It has good output symmetry, a compact structure, easy installation, and a wide range of specifications. Product Application: MK208-T Square S-type
Capacity:
500N(50kg)、 1 kN(100kg)、2 kN(200kg)、3 kN(300kg)、5 kN(500kg)、10 kN(1t)、15KN(1.5t) 、20 kN(2t)、30 kN(3t)、50 kN(5t)
|
NO. |
Technical parameters |
|
|
1 |
rated load |
50kg-5t |
|
2 |
comprehensive accuracy |
≥2.0mV/V |
|
3 |
sensitivity |
≤0.05%F.S |
|
4 |
nonlinearity |
≤0.2%F.S |
|
5 |
repeatability |
≤0.2%F.S |
|
6 |
hysteresis |
≤0.2%F.S |
|
7 |
input impedance |
350Ω±10Ω |
|
8 |
output impedance |
350Ω±2 |
|
9 |
Temperature effect on zero |
±0.03%F.S/10°C |
|
10 |
insulation resistance |
≥5000MΩ |
|
11 |
excitation voltage |
10-12VDC |
|
12 |
Operating Temperature Range |
-10°C~+70°C |
|
13 |
Allowable overload range |
120%F.S |
|
14 |
Wiring Method |
Red... E+ (positive power supply) Black...E-( negative power supply) Green... S+ (positive signal) White... S- (negative signal) |

English